New ABB Contactor AX80-30-00-84 3-Phase Motor and Circuit Control Up to 690 VAC
$ 158.4
- Description
- Size Guide
Description
New ABB Contactor AX80-30-00-84 is mainly used for controlling 3-phase motors and powers circuits up to 690 VAC.*Block type design
*3 main poles
*AC operated
*Optional auxiliary contact blocks may be added
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4755 >> Contactors
General Use Rating UL/CSA:
(600 V AC) 105 A
Horsepower Rating UL/CSA:
(120 V AC) Single Phase 7-1/2 Hp
(240 V AC) Single Phase 15 Hp
(200 ... 208 V AC) Three Phase 25 Hp
(220 ... 240 V AC) Three Phase 30 Hp
(440 ... 480 V AC) Three Phase 60 Hp
(550 ... 600 V AC) Three Phase 75 Hp
Tightening Torque UL/CSA:
Auxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 35 in·lb
Environmental
Ambient Air Temperature:
Close to Contactor for Storage -60 ... +80 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C
Close to Contactor without Thermal O/L Relay -40 ... +70 °C
Near Contactor for Operation in Free Air -40 ... +70 °C
Climatic Withstand:
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible:
3000 m
RoHS Status:
Following EU Directive 2002/95/EC August 18, 2005 and amendment
Technical
Number of Main Contacts NO:
3
Rated Operational Voltage:
Auxiliary Circuit 690 V
Main Circuit 690 V
Rated Frequency (f):
Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (I
th
):
acc. to IEC 60947-4-1, Open Contactors q = 40 °C 125 A
Rated Operational Current AC-1 (I
e
):
(690 V) 40 °C 125 A
(690 V) 70 °C 85 A
(220 / 240 V) 55 °C 105 A
Rated Operational Current AC-3 (I
e
):
(220 / 230 / 240 V) 55 °C 80 A
(380 / 400 V) 55 °C 80 A
(415 V) 55 °C 80 A
(440 V) 55 °C 70 A
(500 V) 55 °C 65 A
(690 V) 55 °C 46 A
Rated Operational Power AC-3 (P
e
):
(220 / 230 / 240 V) 22 kW
(380 / 400 V) 37 kW
(415 V) 40 kW
(440 V) 40 kW
(500 V) 45 kW
(690 V) 40 kW
Rated Short-time Withstand Current (I
cw
):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
for 1 s -empty- A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
Maximum Electrical Switching Frequency:
AC-1 600 cycles per hour
AC-3 600 cycles per hour
Rated Insulation Voltage (U
i
):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (U
imp
):
6 kV
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (U
c
):
50 Hz 110 V
60 Hz 110 ... 120 V